To the top of the document
Orlando
   
GMDE Start Page Load static TOC Load dynamic TOC Help?

Fluid Pump Selective Measurement


1898044

Callout

Component Name

1

A/Trans Fluid Pump Body

Tip
Measure the distance from the bottom of the gauge bar to the bottom of the pump rotor cavity. Refer to Fluid Pump Selective Specifications .

Special Tool

GE 34673 Flat Gauge Bar or equivalent

2

A/Trans Fluid Pump Driven Gear

Tip
Refer to Fluid Pump Selective Specifications to select the correct gear.

3

A/Trans Fluid Pump Drive Gear

Tip
Refer to Fluid Pump Selective Specifications to select the correct gear.

   


© Copyright Chevrolet. All rights reserved
   


© Copyright Chevrolet. All rights reserved