To the top of the document
Orlando
   
GMDE Start Page Load static TOC Load dynamic TOC Help?

Molex Connectors

Special Tools

    • EL-38125-580 Terminal Release Tool Kit
    • J-38125-213 Terminal Release Tool

For equivalent regional tools, refer to Special Tools .

Terminal Removal Procedure

  1. Locate the connector position assurance (CPA) on the top of the wire dress cover. Slide the CPA forward.

  2. 1709320
  3. Slide the lever lock forward while pressing down on the lever lock release tab.

  4. 1709258
  5. The lever should be in the full forward position.

  6. 1709322
  7. Disconnect the connector from the component.

  8. 1572878
  9. Remove the dress cover by using a flat bladed tool to release the dress cover locking tabs and lift up on the dress cover.
  10. Cut the tie wrap that holds the wires to the connector body.

  11. 1572905
  12. Use a small flat-blade tool to prise one side of the nose piece up to the pre-stage position. When the nose piece is in the pre-staged position, the nose piece will be raised above the connector body the length of the step in the nose piece.

  13. 1572908
  14. Use a small flat-blade tool to prise the other side of the piece to the pre-stage position. If the nose piece is higher than the first step in the nose piece, gently push down on the nose piece until it meets with resistance from the connector body, you should feel the nose piece click into position.

  15. 1572911
  16. Insert the J-38125-213 into the small terminal release hole on the nose piece and gently pull on the back of the wire.
  17. Repair the terminal by following the Repairing Connector Terminals procedure.
  18. Insert the repaired terminal back into the cavity. Repeat the diagnostic procedure to verify the repair and reconnect the connector bodies.

Terminated Lead Repair

  1. Remove the terminal.
  2. Find the appropriate terminated lead.
  3. Use the appropriate splice sleeves depending on the gauge size.
  4. Refer to Splicing Copper Wire Using Splice Sleeves .

Terminal Insertion Procedure

After the terminal is replaced, perform the following procedure in order to insert the terminal.

  1. Slide the new terminal into the correct cavity at the back of the connector.
  2. Push the terminal into the connector until it locks into place. The new terminal should be even with the other terminals. Insure that the terminal is locked in place by gently pulling on the wire.
  3. To assemble the connector, reverse the connector disassembly procedure.
   


© Copyright Chevrolet. All rights reserved
   


© Copyright Chevrolet. All rights reserved