To the top of the document
Orlando
   
GMDE Start Page Load static TOC Load dynamic TOC Help?

Exhaust Gas Recirculation Valve Cooler Bypass Control Solenoid Valve Replacement

Removal Procedure

  1. Remove the engine sight shield. Refer to Engine Sight Shield Replacement .

  2. 2511766
  3. Disconnect the exhaust gas recirculation bypass control solenoid valve wiring harness plug (2).
  4. Remove the 2 exhaust gas recirculation bypass control solenoid valve hoses (3).
  5. Remove the 2 exhaust gas recirculation bypass control solenoid valve bolts (1).
  6. Remove the exhaust gas recirculation valve cooler bypass control solenoid valve (4).

Installation Procedure


    2511766
  1. Install the exhaust gas recirculation valve cooler bypass control solenoid valve (4).
  2. Caution: Refer to Fastener Caution in the Preface section.

  3. Install the 2 exhaust gas recirculation bypass control solenoid valve bolts (1) and tighten to 6 N·m (53 lb in).
  4. Install the 2 exhaust gas recirculation bypass control solenoid valve hoses (3).
  5. Connect the exhaust gas recirculation bypass control solenoid valve wiring harness plug (2).
  6. Install the engine sight shield. Refer to Engine Sight Shield Replacement .
   