Orlando
Vacuum Pump Hose Replacement
Removal Procedure
Remove the engine sight shield. Refer to
Engine Sight Shield Replacement
.
Remove the vacuum pump hose (2) from the vacuum pump (1).
Remove the vacuum pump hose from the 2 vacuum pump hose clips (3).
Remove the wiring harness conduit (1) in top direction from the 3 exhaust gas recirculation cooler brackets. Hang the wiring harness conduit aside.
Remove the vacuum pump hose (3) from the exhaust gas recirculation valve cooler bypass control solenoid valve (5).
Remove the 3 vacuum pump hose clips (2).
Remove the vacuum pump hose (3) from the charge air bypass valve vacuum tank (4).
Installation Procedure
Install the vacuum pump hose (3) to the charge air bypass valve vacuum tank (4).
Install the 3 vacuum pump hose clips (2).
Install the vacuum pump hose (3) to the exhaust gas recirculation valve cooler bypass control solenoid valve (5).
Install the wiring harness conduit (1) to the 3 exhaust gas recirculation cooler brackets.
Install the vacuum pump hose to the 2 vacuum pump hose clips (3).
Install the vacuum pump hose (2) to the vacuum pump (1).
Install the engine sight shield. Refer to
Engine Sight Shield Replacement
.
© Copyright Chevrolet. All rights reserved
© Copyright Chevrolet. All rights reserved