Blower Motor Control Module Replacement -- Right Hand Drive
Removal Procedure
Disconnect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
.
Remove the instrument panel (I/P) compartment. Refer to
Instrument Panel Compartment Replacement
.
Remove the left side floor air outlet duct. Refer to
Floor Air Outlet Duct Replacement - Left Side
:
Right Hand Drive
→
Left Hand Drive
.
Disconnect the electrical connectors.
Remove the blower motor control module screws (1).
Remove the blower motor control module (2).
Installation Procedure
Install the blower motor control module (2).
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the blower motor control module screws (1) and tighten to
1.2 N·m (11 lb in)
.
Connect the electrical connector.
Install the left side floor air outlet duct. Refer to
Floor Air Outlet Duct Replacement - Left Side
:
Right Hand Drive
→
Left Hand Drive
.
Install the I/P compartment. Refer to
Instrument Panel Compartment Replacement
.
Connect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
.