Spark
   
GMDE Start Page Load static TOC Load dynamic TOC Help?

Blower Motor Control Module Replacement -- Right Hand Drive

Removal Procedure

  1. Disconnect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection .
  2. Remove the instrument panel (I/P) compartment. Refer to Instrument Panel Compartment Replacement .
  3. Remove the left side floor air outlet duct. Refer to Floor Air Outlet Duct Replacement - Left Side : Right Hand Drive → Left Hand Drive .

  4. 2343800
  5. Disconnect the electrical connectors.
  6. Remove the blower motor control module screws (1).
  7. Remove the blower motor control module (2).

Installation Procedure


    2343800
  1. Install the blower motor control module (2).
  2. Caution: Refer to Fastener Caution in the Preface section.

  3. Install the blower motor control module screws (1) and tighten to 1.2 N·m (11 lb in).
  4. Connect the electrical connector.
  5. Install the left side floor air outlet duct. Refer to Floor Air Outlet Duct Replacement - Left Side : Right Hand Drive → Left Hand Drive .
  6. Install the I/P compartment. Refer to Instrument Panel Compartment Replacement .
  7. Connect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection .
   