To the top of the document
Captiva
   
GMDE Start Page Load static TOC Load dynamic TOC Help?

Control Solenoid Valve and Transmission Control Module Assembly Replacement

Removal Procedure

  1. Remove the transmission control valve body cover. Refer to Control Valve Body Cover Replacement .

  2. 1998829
  3. Disconnect the input speed sensor electrical connector (1).
  4. Disconnect the output speed sensor electrical connector (2).
  5. Disconnect the shift position switch electrical connector (3).

  6. 1998830
  7. Remove the 3 control valve body bolts (1) M5 x 40.5.
  8. Remove the 12 control valve body bolts (2) M6 x 97.
  9. Remove the control solenoid valve assembly (3) with transmission control module.
  10. Caution: Use care when removing or installing the filter plate assembly. A broken or missing retaining tab may not adequately secure the filter plate to the control solenoid valve assembly, resulting in possible damage or contamination.

  11. Remove the control solenoid valve assembly filter plate (4). Discard the filter plate. It is not reusable.
  12. Inspect the pressure switch seals for damage or contamination. Replace the control solenoid valve assembly as necessary.
  13. Inspect the channel plate bolt pass through holes for damage or burnelling. Any damage could cause leaking. Replace as necessary.

Installation Procedure


    1998830

    Caution: Use care when removing or installing the filter plate assembly. A broken or missing retaining tab may not adequately secure the filter plate to the control solenoid valve assembly, resulting in possible damage or contamination.

  1. Install a NEW control solenoid valve assembly filter plate (4) to prevent fluid leaks past the fluid seals.
  2. Install the control solenoid valve assembly (3) with transmission control module.
  3. Hand start the control valve body bolts (1, 2).
  4. Caution: Refer to Fastener Caution in the Preface section.


    2000158
  5. Secure the 12 control valve body bolts (2) M6 x 97 and tighten in sequence to 10 N·m (89 lb in).
  6. Secure the 3 control valve body bolts (1) M5 x 40.5 and tighten in sequence to 8 N·m (71 lb in).

  7. 1998829
  8. Connect the input speed sensor electrical connector (1).
  9. Connect the output speed sensor electrical connector (2).
  10. Connect the shift position switch electrical connector (3).
  11. Install the transmission control valve body cover. Refer to Control Valve Body Cover Replacement .
  12. If a NEW TCM has been installed into the vehicle, the NEW module needs to be reprogrammed. Refer to Service Programming System (SPS) .
  13. Note: The Service Fast Learn Adapts procedure must be performed when one of the following repairs have been made to the vehicle. Failure to perform the procedure after one of the following repairs may result in poor transmission performance, as well as transmission DTCs being set:

       • Transmission internal service/overhaul
       • Valve body repair or replacement
       • Control solenoid valve assembly replacement
       • TCM software/calibration update
       • Any service in response to a shift quality concern

  14. Perform the service fast learn adapts. Refer to Service Fast Learn Adapts .
   


© Copyright Chevrolet. All rights reserved