Problem
| Causes
|
DEFINITION: During the fuelling process a continual, occasional or no fuel nozzle shut-off condition has occurred.
|
Difficult to fill
|
• | Fuel fill limiter vent valve stuck closed |
• | Evaporative emission (EVAP) canister restricted |
• | EVAP vent valve stuck closed |
• | Hose between canister and canister vent solenoid twisted or kinked if applicable |
• | Fuel filler hose is kinked |
• | Faulty dispensing nozzle |
• | Ignition switch ON, vent valve closed |
|
Over fill
|
• | Fill limiter vent valve stuck open or leaking |
• | Fuel inlet check valve stuck open |
|
Pre-mature shut-off of the fuel dispensing nozzle occurs immediately after engaging dispensing nozzle, tank empty
|
• | Restricted vapour lines or fuel fill pipe |
• | Inlet check valve at tank stuck closed, fill pipe full of fuel |
• | Fuel tank full, gauge not accurate |
|
Pre-mature shut-off of the fuel dispensing nozzle, more than 1/8 of tank capacity dispensed
|
• | Kinked, pinched or plugged lines in fuel tank vent system |
• | EVAP vent valve stuck closed or restricted |
• | EVAP canister restricted |
• | Fuel limiting vent valve stuck closed or obstruction at top of fuel tank |
|
Fuel Spitback
|
• | Restricted EVAP canister |
• | Ignition switch ON, EVAP vent valve closed |
|