- Clean the sealing surfaces.
- Apply approximately a 3.5 mm (0.138 in) thick bead of sump sealant to the joints (arrows). Refer to Adhesives, Fluids, Lubricants, and Sealers for the recommended sealant.
Note: The assembly time, including torque check, must take no longer than 10 minutes.
- Apply approximately a 3.5 mm (0.138 in) thick bead of sump sealant (1) to the sump. Refer to Adhesives, Fluids, Lubricants, and Sealers for the recommended sealant.
- Install the sump (2).
- Install the 15 sump bolts (1).
Caution: Refer to Fastener Caution in the Preface section.
- Tighten the sump bolts on the cylinder block to 10 N·m (89 lb in).