Exhaust Temperature Sensor Installation - Position 3
Special Tools
EN-50430 Adaptor Exhaust Temperature Sensor .
For equivalent regional tools, refer to Special Tools .
Caution: Refer to Fastener Caution in the Preface section.
- Install the exhaust temperature sensor - position 3 (2) and tighten to 45 N·m (33 lb ft), using the EN-50430 adaptor .
- Clip in the 2 exhaust temperature sensor wiring harness clips to the charge air control vacuum pipe (1).
© Copyright Chevrolet. All rights reserved |