• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Stepper Motors 12V Reference | B023A 02, B0223 06, B0233 06, B0408 06 | B0223 06, B0233 06, B0408 06 | -- | -- |
Air Temperature Actuator - Left Control 1 | B0408 06 | B0408 06 | B0408 01 | 1 |
Air Temperature Actuator - Left Control 2 | B0408 06 | B0408 06 | B0408 01 | 1 |
Air Temperature Actuator - Left Control 3 | B0408 06 | B0408 06 | B0408 01 | 1 |
Air Temperature Actuator - Left Control 4 | B0408 06 | B0408 06 | B0408 01 | 1 |
1. Air Temperature Malfunction |
With the temperature switch at the HVAC controls, the desired air temperature flap position can be put in. The selected value is passed to the HVAC control module via the LIN-Bus. The HVAC control module supplies a 12 V reference voltage to the stepper motor and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motor puts the mixed air flap into the calculated position, in order to reach the selected temperature.
Check the following mechanical fault sources:
• | Air distribution box |
• | Air distribution hoses/air distribution ducts |
HVAC Schematics : Automatic
Automatic HVAC Description and Operation
Control Module References for scan tool information
⇒ | If not within the specified range |
Refer to DTC B0163 or B0183 . |
⇓ | If within the specified range |
⇒ | If not within the specified range |
Refer to DTC B0173, B0178, or B3933 . |
⇓ | If within the specified range |
⇒ | If not within the specified range |
Refer to DTC B0173, B0178, or B3933 . |
⇓ | If within the specified range |
⇒ | If not within the specified range |
Refer to DTC B0163 or B0183 . |
⇓ | If within the specified range |
⇒ | If the A/C compressor cannot be activated or deactivated |
Refer to Air Conditioning Compressor Malfunction . |
⇓ | If the A/C compressor can be activated and deactivated |
⇒ | If not the specified value |
Replace the A26 HVAC Controls. |
⇓ | If the specified value |
⇒ | If the M6L Air Temperature Door Actuator - Left cannot be put into all positions |
Replace the K33 HVAC Control Module. |
⇓ | If the M6L Air Temperature Door Actuator - Left can be put into all positions |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Temperature Valve Actuator Replacement : Right Hand Drive → Left Hand Drive |
• | Control Module References for HVAC control module replacement, setup, and programming |