Basic Digital Multi-meter Requirements
Digital Multimeter (DMM) Basic Requirements
Service information is validated using digital multimeters that meet or exceed the following requirements. Using a multimeter that does not meet these basic requirements may give inaccurate readings which could lead to an incorrect diagnosis.
Display and Settings
- Four digits displayed
- Voltage, amperage, resistance, frequency, diode test settings, and min-max function
- Display positive and negative values
Voltage
- Have at least 10 MΩ input impedance
- Test a DC voltage range of 0.1-1000 V.
- Test an AC voltage range of 0.1-1000 V.
Amperage
- Test a DC amperage range of 0.1[micro ]A-10 A.
- Test an AC amperage range of 0.1[micro ]A-10 A.
Resistance
Test a resistance range of 0.1 Ω-40 MΩ and displays infinite for a value greater than 40 MΩ (O.L. (Over-load))
Frequency
Test for a frequency range of 0.5 HZ-199 K HZ
Diode Test
- Apply at least 1 mA when performing the diode bias test
- Display the break over voltage drop (0-3 V) of a forward biased diode
- Display infinite (O.L. (Over-load)) when a diode is reverse biased
Min-Max Readings
- Can update at a 1 ms sample rate
- Saves and displays minimum and maximum values