To the top of the document
Orlando
   
GMDE Start Page Load static TOC Load dynamic TOC Help?

Exhaust Temperature Sensor Installation - Position 3

Special Tools

EN-50430 Adaptor Exhaust Temperature Sensor .

For equivalent regional tools, refer to Special Tools .

    Caution: Refer to Fastener Caution in the Preface section.


    2373115
  1. Install the exhaust temperature sensor - position 3 (2) and tighten to 45 N·m (33 lb ft), using the EN-50430 adaptor .
  2. Clip in the 2 exhaust temperature sensor wiring harness clips to the charge air control vacuum pipe (1).
   


© Copyright Chevrolet. All rights reserved
   


© Copyright Chevrolet. All rights reserved