Repairing Damaged Wire Insulation

Table 1: Wire Size Conversion

If the wire insulation has been chafed, or broken, enough to show the conductive portion of the wire, and the wire is not damaged, determine the length of insulation that needs to be repaired. If the repair is less than 280 mm (11 in), cut the wire within the damaged area. Then slide the appropriate heat shrink tubing (listed below) over the wire, and repair the wire by splicing the wires together. Refer to Splicing Copper Wire Using Splice Sleeves . Once the wire is spliced together slide heat shrink tubing over the damaged area and apply heat to seal the repaired wire.

If the wire is damaged, or the damaged area is larger than 280 mm (11 in), then replace the damaged wire by splicing in a new section of wire. Refer to Splicing Copper Wire Using Splice Sleeves .

GM Part Number

Diameter

Description

Colour

Length

Metric

English

Metric

English

12355003

9.5 mm

0.375 in

Tubing, Shrink 3/8

Black

305 mm

12 in

12355005

12.7 mm

0.5 in

Tubing, Shrink 1/2

Black

305 mm

12 in

12355011

19.1 mm

0.75 in

Tubing, Shrink 3/4

Black

305 mm

12 in

12355008

25.4 mm

1.0 in

Tubing, Shrink 1.00

Black

305 mm

12 in

Wire Size Conversion

Metric Wire Sizes (mm 2)

AWG Sizes

0.13

26

0.21

24

0.32

22

0.52

20

0.83

18

1.31

16

2.09

14

3.31

12

5.27

10

8.37

8

13.3

6

21.2

4

33.6

2

53.5

1/0

   


© Copyright Chevrolet. All rights reserved