Orlando |
||||||||
|
|
• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Stepper Motors 12V Reference | B023A 02, B0223 06, B0233 06, B0408 06 | B0223 06, B0233 06, B0408 06 | -- | -- |
Recirculation Actuator Control 1 | B0223 06 | B0223 06 | B0223 01 | 1 |
Recirculation Actuator Control 2 | B0223 06 | B0223 06 | B0223 01 | 1 |
Recirculation Actuator Control 3 | B0223 06 | B0223 06 | B0223 01 | 1 |
Recirculation Actuator Control 4 | B0223 06 | B0223 06 | B0223 01 | 1 |
Air Temperature Actuator - Left Control 1 | B0408 06 | B0408 06 | B0408 01 | 2 |
Air Temperature Actuator - Left Control 2 | B0408 06 | B0408 06 | B0408 01 | 2 |
Air Temperature Actuator - Left Control 3 | B0408 06 | B0408 06 | B0408 01 | 2 |
Air Temperature Actuator - Left Control 4 | B0408 06 | B0408 06 | B0408 01 | 2 |
Mode Actuator Control 1 | B0233 06 | B0233 06 | B0233 01 | 3 |
Mode Actuator Control 2 | B0233 06 | B0233 06 | B0233 01 | 3 |
Mode Actuator Control 3 | B0233 06 | B0233 06 | B0233 01 | 3 |
Mode Actuator Control 4 | B0233 06 | B0233 06 | B0233 01 | 3 |
1. Air Recirculation Malfunction 2. Air Temperature Malfunction 3. Air Distribution Malfunction |
Stepper motors are used for temperature regulation, air distribution control and recirculation flap control.
With the appropriate switches at the HVAC controls, the desired air temperature flap position, air distribution flap position and recirculation flap position can be put in. The selected values are passed to the HVAC control module via the local interconnect network (LIN) Bus. The HVAC control module supplies a 12 V reference voltage to the stepper motors and energises the 4 stepper motor coils with a pulsed ground signal. The stepper motors put the appropriate flap into the calculated position, in order to reach the put in temperature/position.
• | Ignition ON |
• | The HVAC control module is ON. |
The stepper motors supply output is shorted to ground.
At least one control output (of 4 possible outputs) of the appropriate stepper motor is shorted to voltage when motor starts moving. Faults are not detected when motor is already running or target position is already reached.
At least one control output (of 4 possible outputs) of the appropriate stepper motor is shorted to ground or open when motor starts moving. Faults are not detected when motor is already running or target position is already reached.
• | The affected output will be switched off for hardware protection. |
• | All stepper motors are deactivated. |
• | The affected output will be switched off for hardware protection. |
• | The affected stepper motor is deactivated. |
The condition for setting the DTC is no longer present.
Manual HVAC Description and Operation
Control Module References for scan tool information
If DTC B023A is present
Refer to Actuator Power Supply Malfunction.
If DTC B023A is not present
If DTC B0223 is present
Refer to Recirculation Actuator Malfunction.
If DTC B0223 is not present
If DTC B0233 is present
Refer to Mode Actuator Malfunction.
If DTC B0233 is not present
If DTC B0408 is present
Refer to Air Temperature Actuator Malfunction.
If DTC B0408 is not present
If less than infinite resistance
Repair the short to ground on the circuit.
If infinite resistance
• | Terminal 16 X3 |
• | Terminal 17 X3 |
• | Terminal 18 X3 |
• | Terminal 19 X3 |
If greater than 0.3 V
Repair the short to voltage on the circuit.
If less than 0.3 V
• | Terminal 16 X3 |
• | Terminal 17 X3 |
• | Terminal 18 X3 |
• | Terminal 19 X3 |
If less than infinite resistance
Repair the short to ground on the circuit.
If infinite resistance
• | M46 Air Recirculation Door Actuator terminal 1 and terminal 16 X3 at the K33 HVAC Control Module harness connector |
• | M46 Air Recirculation Door Actuator terminal 2 and terminal 15 X3 at the K33 HVAC Control Module harness connector |
• | M46 Air Recirculation Door Actuator terminal 3 and terminal 17 X3 at the K33 HVAC Control Module harness connector |
• | M46 Air Recirculation Door Actuator terminal 4 and terminal 18 X3 at the K33 HVAC Control Module harness connector |
• | M46 Air Recirculation Door Actuator terminal 6 and terminal 19 X3 at the K33 HVAC Control Module harness connector |
If greater than 5 Ω
Repair the open/high resistance in the circuit.
If less than 5 Ω
If DTC resets
Replace the K33 HVAC Control Module.
If DTC does not reset
• | Terminal 2 X3 |
• | Terminal 3 X3 |
• | Terminal 4 X3 |
• | Terminal 5 X3 |
If greater than 0.3 V
Repair the short to voltage on the circuit.
If less than 0.3 V
• | Terminal 2 X3 |
• | Terminal 3 X3 |
• | Terminal 4 X3 |
• | Terminal 5 X3 |
If less than infinite resistance
Repair the short to ground on the circuit.
If infinite resistance
• | M37 Mode Door Actuator terminal 1 and terminal 2 X3 at the K33 HVAC Control Module harness connector |
• | M37 Mode Door Actuator terminal 2 and terminal 15 X3 at the K33 HVAC Control Module harness connector |
• | M37 Mode Door Actuator terminal 3 and terminal 3 X3 at the K33 HVAC Control Module harness connector |
• | M37 Mode Door Actuator terminal 4 and terminal 4 X3 at the K33 HVAC Control Module harness connector |
• | M37 Mode Door Actuator terminal 6 and terminal 5 X3 at the K33 HVAC Control Module harness connector |
If greater than 5 Ω
Repair the open/high resistance in the circuit.
If less than 5 Ω
If DTC resets
Replace the K33 HVAC Control Module.
If DTC does not reset
• | Terminal 11 X3 |
• | Terminal 12 X3 |
• | Terminal 13 X3 |
• | Terminal 14 X3 |
If greater than 0.3 V
Repair the short to voltage on the circuit.
If less than 0.3 V
• | Terminal 11 X3 |
• | Terminal 12 X3 |
• | Terminal 13 X3 |
• | Terminal 14 X3 |
If less than infinite resistance
Repair the short to ground on the circuit.
If infinite resistance
• | M6L Air Temperature Door Actuator - Left terminal 1 and terminal 11 X3 at the K33 HVAC Control Module harness connector |
• | M6L Air Temperature Door Actuator - Left terminal 2 and terminal 15 X3 at the K33 HVAC Control Module harness connector |
• | M6L Air Temperature Door Actuator - Left terminal 3 and terminal 12 X3 at the K33 HVAC Control Module harness connector |
• | M6L Air Temperature Door Actuator - Left terminal 4 and terminal 13 X3 at the K33 HVAC Control Module harness connector |
• | M6L Air Temperature Door Actuator - Left terminal 6 and terminal 14 X3 at the K33 HVAC Control Module harness connector |
If greater than 5 Ω
Repair the open/high resistance in the circuit.
If less than 5 Ω
If DTC resets
Replace the K33 HVAC Control Module.
If DTC does not reset
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Air Inlet Valve Actuator Replacement : Right Hand Drive → Left Hand Drive |
• | Temperature Valve Actuator Replacement : Right Hand Drive → Left Hand Drive |
• | Mode Control Cam Actuator Replacement : Right Hand Drive → Left Hand Drive |
• | Control Module References for HVAC control module replacement, setup, and programming |