Exhaust Gas Recirculation Valve Replacement

Removal Procedure

  1. Remove the engine sight shield. Refer to Engine Sight Shield Replacement .
  2. Disconnect exhaust gas recirculation valve wiring harness plug.

  3. 2373160
  4. Remove the 3 exhaust gas recirculation valve bolts (2).
  5. Remove the exhaust gas recirculation valve (1) and the gasket (3).

Installation Procedure


    2373160
  1. Install the exhaust gas recirculation valve (1) and a NEW gasket (3).
  2. Caution: Refer to Fastener Caution in the Preface section.

  3. Install the 3 exhaust gas recirculation valve bolts (2) and tighten to 25 N·m (18 lb ft).
  4. Connect exhaust gas recirculation valve wiring harness plug.
  5. Install the engine sight shield. Refer to Engine Sight Shield Replacement .
   


© Copyright Chevrolet. All rights reserved