Air Cleaner Replacement

Removal Procedure


    2506247
  1. Disconnect the mass air flow sensor wiring harness plug (1) from mass air flow sensor.
  2. Unclip the mass air flow sensor wiring harness clip (2) from the air filter assembly.

  3. 2506246
  4. Remove the air filter outlet duct (1) from the mass air flow sensor.
  5. Remove the 6 air filter housing bolts (2).
  6. Remove the air cleaner housing cover (3).
  7. Remove the air cleaner element (4).

Installation Procedure


    2506246
  1. Install the air cleaner element (4).
  2. Install the air cleaner housing cover (3).
  3. Install the 6 air filter housing bolts (2).
  4. Install the air filter outlet duct (1) to the mass air flow sensor.

  5. 2506247
  6. Clip in the mass air flow sensor wiring harness clip (2) to the air filter assembly.
  7. Connect the mass air flow sensor wiring harness plug (1) to the mass air flow sensor.
   