To the top of the document
Orlando
   
GMDE Start Page Load static TOC Load dynamic TOC Help?

Radiator Outlet Hose Replacement — 1.8L 2H0

Removal Procedure

  1. Disconnect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection : without Start/Stop System .
  2. Drain the cooling system. Refer to Cooling System Draining and Filling .

  3. 2512565
  4. Loosen the hose clamp (1).
  5. Remove the radiator outlet hose assembly (3) from the water pump.
  6. Unclip the clamp (2).
  7. Remove the radiator outlet hose assembly (3) from the radiator.

Installation Procedure


    2512565
  1. Install the radiator outlet hose assembly (3) to the radiator.
  2. Clip in the clamp (2).
  3. Install the radiator outlet hose assembly (3) to the water pump.
  4. Install the hose clamp (1).
  5. Fill the cooling system. Refer to Cooling System Draining and Filling .
  6. Connect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection : without Start/Stop System .
   


© Copyright Chevrolet. All rights reserved