To the top of the document
Cruze
   
GMDE Start Page Load static TOC Load dynamic TOC Help?

Manual Shift Detent Lever with Shaft Position Switch Assembly and Park Pawl Actuator Installation

Table 1: Park Pawl Actuator Guide Installation
Table 2: Park Pawl Actuator Installation

Park Pawl Actuator Guide Installation


1891435

Park Pawl Actuator Guide Installation

Callout

Component Name

1

Park Pawl Actuator Guide Assembly Seal

2

Park Pawl Actuator Guide Assembly

3

Park Pawl Actuator Guide Pin

Caution: Refer to Fastener Caution in the Preface section.

Procedure

Install the Park Pawl Actuator Guide Pin to correct height.

Tighten
7.2 mm (0.28 in)

Park Pawl Actuator Installation


1891436

Park Pawl Actuator Installation

Callout

Component Name

1

Park Pawl Actuator Assembly

2

Manual Shift Detent (w/Shaft Position Switch) Lever Assembly

3

Manual Shaft

Tip
Lubricate the shaft with ATF to prevent damage to the manual shift shaft seal during installation.

4

Manual Shaft Detent Lever Hub Pin

Caution: Refer to Fastener Caution in the Preface section.

Procedure

Install the Manual Shaft Detent Lever Hub Pin to correct height.

Tip
Use a NEW pin to ensure proper engagement with the shaft.

Specification
Install the Manual Shaft Detent Lever Hub Pin to height of (b) 7.9 mm (0.38 in) (b).

Special Tools

DT-48550 Detent Lever Pin Remover

For equivalent regional tools, refer to Special Tools .

5

Manual Shift Shaft Pin

Caution: Use the manual shaft pin installer to install the pin at the correct height in order to properly secure the manual shaft. If you install the pin too deep, the case bore may crack.

Procedure

Inspect pin installed height is within (a).

Tip
Use a NEW pin to ensure proper engagement with the case.

Specification
Inspect pin installed height is within (a) 7.2-8.2 mm (0.28-0.32 in) (a).

Special Tools

DT-41229 Manual Shaft Pin Installer

For equivalent regional tools, refer to Special Tools .

   


© Copyright Chevrolet. All rights reserved