To the top of the document
Cruze
   
GMDE Start Page Load static TOC Load dynamic TOC Help?

Exhaust Gas Recirculation Valve Replacement

Removal Procedure


    2189021
  1. Open the bonnet.
  2. Remove the exhaust gas recirculation pipe. Refer to Exhaust Gas Recirculation Pipe Replacement .
  3. Remove the 2 exhaust gas recirculation valve bolts (1).
  4. Remove the exhaust gas recirculation valve (2).
  5. Remove the exhaust gas recirculation valve gasket (3).

Installation Procedure


    2189021
  1. Install a NEW exhaust gas recirculation valve gasket (3).
  2. Install the exhaust gas recirculation valve (2).
  3. Caution: Refer to Fastener Caution in the Preface section.

  4. Install the 2 exhaust gas recirculation valve bolts (1) and tighten to 25 N·m (19 lb ft).
  5. Install the exhaust gas recirculation pipe. Refer to Exhaust Gas Recirculation Pipe Replacement .
  6. Close the bonnet.
   


© Copyright Chevrolet. All rights reserved