Cruze
Exhaust Gas Recirculation Valve Replacement
Removal Procedure
Open the bonnet.
Remove the exhaust gas recirculation pipe. Refer to
Exhaust Gas Recirculation Pipe Replacement
.
Remove the 2 exhaust gas recirculation valve bolts (1).
Remove the exhaust gas recirculation valve (2).
Remove the exhaust gas recirculation valve gasket (3).
Installation Procedure
Install a NEW exhaust gas recirculation valve gasket (3).
Install the exhaust gas recirculation valve (2).
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the 2 exhaust gas recirculation valve bolts (1) and tighten to
25 N·m (19 lb ft).
Install the exhaust gas recirculation pipe. Refer to
Exhaust Gas Recirculation Pipe Replacement
.
Close the bonnet.
© Copyright Chevrolet. All rights reserved