Exhaust Gas Recirculation Valve Cooler Bypass Control Solenoid Valve Replacement
Removal Procedure
Remove the engine sight shield. Refer to
Engine Sight Shield Replacement
.
Disconnect the exhaust gas recirculation bypass control solenoid valve wiring harness plug (2).
Remove the 2 exhaust gas recirculation bypass control solenoid valve hoses (3).
Remove the 2 exhaust gas recirculation bypass control solenoid valve bolts (1).
Remove the exhaust gas recirculation valve cooler bypass control solenoid valve (4).
Installation Procedure
Install the exhaust gas recirculation valve cooler bypass control solenoid valve (4).
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the 2 exhaust gas recirculation bypass control solenoid valve bolts (1) and tighten to
6 N·m (53 lb in)
.
Install the 2 exhaust gas recirculation bypass control solenoid valve hoses (3).
Connect the exhaust gas recirculation bypass control solenoid valve wiring harness plug (2).
Install the engine sight shield. Refer to
Engine Sight Shield Replacement
.