Exhaust Temperature Sensor Installation - Position 2

Special Tools

EN-50429 Adaptor Exhaust Temperature Sensor .

For equivalent regional tools, refer to Special Tools .

    Caution: Refer to Fastener Caution in the Preface section.


    2373114
  1. Install the exhaust temperature sensor - position 2 (1) and tighten to 45 N·m (33 lb ft), using the EN-50429 adaptor .
  2. Clip in the 2 exhaust temperature sensor wiring harness clips (2) to the exhaust pressure sensor bracket.
   