Cruze |
||||||||
|
|
• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The keyless entry control module receives a discrete input from the driver and passenger door open switch signal circuits. The driver window motor or driver window switch receives a discrete input from the driver door ajar switch signal circuit. The passenger window switch receives a discrete input from the passenger door ajar switch signal circuit.. The door open switches and the door ajar switches are integral to each door catch assembly. When a door is opened, the normally open door open and door ajar switch closes. With the door open switch closed, ground is provided to the door open switch signal circuit. The window switches communicate the door ajar data via serial data communication with the keyless entry control module.
Battery voltage is between 9-16 V.
The keyless entry control module detects a short-circuit to voltage on the driver door release enable circuit for 30 s.
The keyless entry control module detects a short-circuit to voltage in the driver door release enable circuit for 30 s.
The keyless entry control module ignores inputs from the exterior door handle switches.
• | This DTC will be current for as long as the fault is present. |
• | When the fault is no longer present, the DTC will be a history DTC. |
• | A history DTC will clear after 50 ignition cycles. |
Door Lock/Indicator Schematics
Power Door Latch Description and Operation
Control Module References for scan tool information
Command the All Door Lock, Driver Door Unlock and Passenger Door(s) Unlock with the scan tool, the doors should perform the lock and unlock function.
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. If the circuit tests normal, replace the K84 Keyless Entry Control Module. |
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. If the circuit tests normal, replace the K84 Keyless Entry Control Module. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for keyless entry control module replacement, setup, and programming |