Note: The left-hand drive is shown. The right-hand drive is similar.
- Install the mode cam levers (3) to the evaporator case assembly.
- Align and install the mode cam (2) to the mode cam levers (3). Rotate the mode cam (2) to verify mode door operation.
- Install the mode cam bracket (1) to the evaporator case assembly.
Caution: Refer to Fastener Caution in the Preface section.
- Install the mode cam bracket screws to the evaporator case assembly and tighten the screws to 1.5 N·m (13 lb in).
- Install the mode actuator to the evaporator case assembly.
- Install the mode actuator screws to the evaporator case assembly and tighten the screws to 1.5 N·m (13 lb in).
- Connect the electrical connector to the mode actuator.
- Install the communication interface module, if equipped. Refer to Communication Interface Module Replacement .
- Install the driver knee bolster. Refer to
Driver Knee Bolster Replacement : Long Body → Short Body .
Note: Any time a mode actuator or the HVAC control module is replaced, the HVAC control module must be calibrated to ensure correct air distribution.
- Calibrate the actuators using the following procedure:
10.1. | Install a scan tool. |
10.2. | Turn ON the ignition, with the engine OFF. |
10.3. | Select HVAC Control Module. |
10.4. | Select Special Functions. |
10.5. | Select recalibrate All Motors. |
10.6. | Select ON, wait 60 seconds. |
- Cycle the ignition and verify correct operation.