To the top of the document
Captiva
   
GMDE Start Page Load static TOC Load dynamic TOC Help?

DTC P0131, P0132, P0137, P0138, P0151, P0152, P0157, P0158, P2A00, P2A01, P2A03, or P2A04 - LF1, LFW, LFX

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    • Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptors

DTC P0131: HO2S Circuit Low Voltage Bank 1 Sensor 1

DTC P0132: HO2S Circuit High Voltage Bank 1 Sensor 1

DTC P0137: HO2S Circuit Low Voltage Bank 1 Sensor 2

DTC P0138: HO2S Circuit High Voltage Bank 1 Sensor 2

DTC P0151: HO2S Circuit Low Voltage Bank 2 Sensor 1

DTC P0152: HO2S Circuit High Voltage Bank 2 Sensor 1

DTC P0157: HO2S Circuit Low Voltage Bank 2 Sensor 2

DTC P0158: HO2S Circuit High Voltage Bank 2 Sensor 2

DTC P2A00: HO2S Circuit Closed Loop Performance Bank 1 Sensor 1

DTC P2A03: HO2S Circuit Closed Loop Performance Bank 2 Sensor 1

Diagnostic Fault Information

Circuit

Short to Ground

High Resistance

Open

Short to Voltage

Signal Performance

HO2S High Signal

P0131, P0137, P0151, P0157

P0132, P0134, P0138, P0140, P0152, P0154, P0158, P0160

P0132, P0134, P0138, P0140, P0152, P0154, P0158, P0160

P0132, P0134, P0138, P0140, P0152, P0154, P0158, P0160

P0133, P013A, P013B, P013C, P013D, P013E, P013F, P014A, P014B, P0153, P1133, P1153, P2A00, P2A03

HO2S Low Signal

P0131, P0137, P0151, P0157

P0132, P0134, P0138, P0140, P0152, P0154, P0158, P0160

P0132, P0134, P0138, P0140, P0152, P0154, P0158, P0160

P0132, P0134, P0138, P0140, P0152, P0154, P0158, P0160

P0133, P013A, P013B, P013C, P013D, P013E, P013F, P014A, P014B, P0153, P1133, P1153, P2A00, P2A03

HO2S Heater Voltage Supply

P0030, P0036, P0050, P0056, P0132, P0135, P0138, P0141, P0152, P0155, P0158, P0161, *

P0030, P0036, P0050, P0056, P0132, P0134, P0135, P0138, P0140, P0141, P0152, P0154, P0155, P0158, P0160, P0161

P0030, P0036, P0050, P0056, P0132, P0134, P0135, P0138, P0140, P0141, P0152, P0154, P0155, P0158, P0160, P0161

P0690

P0135, P0141, P0155, P0161

HO2S Heater Control

P0030, P0036, P0050, P0053, P0054, P0056, P0059, P0060, P0135, P0141, P0155, P0161

P0030, P0036, P0050, P0056, P0132, P0134, P0135, P0138, P0140, P0141, P0152, P0154, P0155, P0158, P0160, P0161

P0030, P0036, P0050, P0056, P0132, P0134, P0135, P0138, P0140, P0141, P0152, P0154, P0155, P0158, P0160, P0161

P0030, P0036, P0050, P0056, P0132, P0134, P0135, P0138, P0140, P0141, P0152, P0154, P0155, P0158, P0160, P0161

P0135, P0141, P0155, P0161

* Opens Fuse

Typical Scan Tool Data

HO2S Sensor 1 Voltage, HO2S Sensor 2 Voltage

Circuit

Short to Ground

Open

Short to Voltage

Parameter Normal Range: 200-800 mV

HO2S High Signal

0.00 V

Approximately 1.27 V

Approximately 1.27 V

HO2S Low Signal

0.00 V

Approximately 1.27 V

Approximately 1.27 V

Circuit/System Description

The heated oxygen sensors (HO2S) are used for fuel control and catalyst monitoring. Each HO2S compares the oxygen content of the surrounding air with the oxygen content of the exhaust stream. When the engine is started, the control module operates in an Open Loop mode, ignoring the HO2S signal voltage while calculating the air-to-fuel ratio. While the engine runs, the HO2S heats up and begins to generate a voltage within a range of 0-1,275 mV. Once sufficient HO2S voltage fluctuation is observed by the control module, Closed Loop is entered. The control module uses the HO2S voltage to determine the air-to-fuel ratio. An HO2S voltage that increases toward 1,000 mV indicates a rich fuel mixture. An HO2S voltage that decreases toward 0 mV indicates a lean fuel mixture.

The heating elements inside each HO2S heat the sensor to bring the sensor up to operating conditions faster. This allows the system to enter Closed Loop earlier and the control module to calculate the air-to-fuel ratio sooner.

Conditions for Running the DTC

P0131, P0137, P0151, or P0157

    • DTCs P0068, P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0201, P0202, P0203, P0204, P0205, P0206, P0207, P0208, P0220, P0222, P0223, P0442, P0443, P0446, P0449, P0455, P0496, P1516, P2101, P2119, P2135, P2176 are not set.
    • The engine is operating in Closed Loop.
    • The Ignition 1 voltage is between 10-32 V.
    • The fuel level is greater than 10 %.
    • The throttle position (TP) is between 3-70 %.
    • The DTCs run continuously when the above conditions are met for 2 s.

P0132, P0138, P0152, or P0158

    • DTCs P0068, P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0201, P0202, P0203, P0204, P0205, P0206, P0207, P0208, P0220, P0222, P0223, P0442, P0443, P0446, P0449, P0455, P0496, P1516, P2101, P2119, P2135, P2176 are not set.
    • The engine is operating in Closed Loop.
    • The Ignition 1 voltage is between 10-32 V.
    • The fuel level is greater than 10 %.
    • The throttle position (TP) is between 0-70 %.
    • The DTCs run continuously when the above conditions are met for 3 s.

P2A00 or P2A03

    • DTCs P0030, P0036, P0053, P0054, P0068, P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0131, P0132, P0133, P0134, P0135, P0137, P0138, P0140, P0141, P0171, P0172, P0174, P0175, P0201, P0202, P0203, P0204, P0205, P0206, P0207, P0208, P0220, P0222, P0223, P0300, P0301, P0302, P0303, P0304, P0305, P0306, P0307, P0308, P0442, P0443, P0446, P0449, P0455, P0496, P1133, P1516, P2101, P2119, P2135, P2176 are not set.
    • The engine is running.
    • The system voltage is between 10-32 V.
    • The ECT Sensor parameter is more than 0°C (32°F).
    • DTCs P2A00 and P2A03 run continuously when the above conditions are met.

Conditions for Setting the DTC

P0131, P0137, P0151, or P0157

    • The ECM detects that the HO2S voltage is less than 50 mV.
    • The DTCs set within 50 s when the above condition is met.

P0132, P0138, P0152, or P0158

    • The ECM detects that the HO2S voltage is greater than 1,050 mV.
    • The DTCs set within 50 s when the above condition is met.

P2A00 or P2A03

    • The ECM detects that the Fuel Control Loop Status parameter is open.
    • DTCs P2A00 and P2A03 set within 30 s when the above condition is met.

Action Taken When the DTC Sets

DTCs P0131, P0132, P0137, P0138, P0151, P0152, P0158, P2A00 and P2A03 are Type B DTCs.

Conditions for Clearing the MIL/DTC

DTCs P0131, P0132, P0137, P0138, P0151, P0152, P0158, P2A00 and P2A03 are Type B DTCs.

Reference Information

Schematic Reference

Engine Controls Schematics

Connector End View Reference

Component Connector End Views

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Heated Oxygen Sensor Wiring Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Verification

  1. Ignition ON, observe the DTC information with a scan tool. Verify no B52 HO2S heater DTCs are set.
  2. If a B52 HO2S heater DTC is set, refer to Diagnostic Trouble Code (DTC) List - Vehicle .
  3. Engine running, observe the appropriate scan tool B52 HO2S voltage parameter. The reading should be within the range of 50-1,050 mV.
  4. Operate the vehicle within the Conditions for Running the DTC to verify the DTC does not reset. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.

Circuit/System Testing

  1. Ignition OFF, disconnect the appropriate B52 HO2S harness connector.
  2. Ignition ON, observe the appropriate scan tool HO2S voltage parameter. The parameter should display 1.27 V.
  3. If less than the specified range, test the high and low signal circuits for a short to ground. If both signal circuits test normal, replace the K20 ECM.
  4. Ignition ON, test for 2.5-3.0 V between the high signal circuit terminal B and ground.
  5. If less than the specified range, test the high signal circuit for an open/high resistance. If the circuit tests normal, replace the K20 ECM.
    If greater than the specified range, test the high signal circuit for a short to voltage. If the circuit tests normal, replace the K20 ECM.
  6. Ignition OFF, connect a 3 A fused jumper wire between the high signal circuit terminal B and the low signal circuit terminal A.
  7. Note: The low signal circuit is tied to a pull-up circuit within the ECM. A voltage of 0.90-1.10 V on the low signal circuit is normal.

  8. Ignition ON, verify the scan tool HO2S parameter displays 0.0 V.
  9. If greater than the specified range, test the low signal circuit for an open/high resistance or for a short to voltage. If the circuit tests normal, replace the K20 ECM.
  10. If all circuits test normal, test or replace the appropriate B52 HO2S.

Repair Instructions

Caution: Refer to Heated Oxygen Sensor Resistance Learn Reset Caution in the Preface section.

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Heated Oxygen Sensor Replacement - Bank 1 Sensor 1
    •  Heated Oxygen Sensor Replacement - Bank 1 Sensor 2 : LF1 or LFW
    •  Heated Oxygen Sensor Replacement - Bank 2 Sensor 1 : LF1 or LFW
    •  Heated Oxygen Sensor Replacement - Bank 2 Sensor 2
    • Control Module References for ECM replacement, setup, and programming
   


© Copyright Chevrolet. All rights reserved