Balancer Cleaning and Inspection
Special Tools
EN-50431 BSM Backlash Measure Adaptor
For equivalent regional tools, refer to Special Tools .
- Remove the coating remains on the balance shaft module gear using an air gun and check the balance shaft module if damaged.
- Install the EN-50431 BSM backlash measure adapter and dial gauge as shown in the graphic. Check that EN-50431 adapter is horizontal.
- Move the balance shaft module gear using a finger and check the backlash specifications (0.046-0.128 mm).
- If the balance shaft module is out of specification, try the procedure (1-3) again.
- If the balance shaft module gear backlash does not meet the specification, replace with new balance shaft module.