Cruze
Exhaust Gas Recirculation Pipe Replacement
Removal Procedure
Open the hood.
Disconnect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
Remove the intake manifold brace. Refer to
Intake Manifold Brace Removal
.
Remove the 4 exhaust gas recirculation pipe bolts (1, 3) from the intake manifold.
Remove the 2 exhaust gas recirculation pipe nuts (5) from the exhaust gas recirculation valve adapter.
Remove the exhaust gas recirculation pipe (4).
Remove the 2 exhaust gas recirculation pipe seals (2, 6).
Installation Procedure
Install the 2 NEW exhaust gas recirculation pipe seals (2, 6).
Install the exhaust gas recirculation pipe (4).
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the 2 exhaust gas recirculation pipe nuts (5) to the exhaust gas recirculation valve adapter and tighten to
10 N·m (89 lb in)
.
Install the 2 exhaust gas recirculation pipe bolts (3) to the intake manifold and tighten to
8 N·m (71 lb in)
.
Install the 2 exhaust gas recirculation pipe bolts (1) to the intake manifold and tighten to
12 N·m (107 lb in)
.
Install the intake manifold brace. Refer to
Intake Manifold Brace Installation
.
Connect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
Close the hood.
© Copyright Chevrolet. All rights reserved