Cruze |
||||||||
|
|
• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Rear Demist Relay Switch B+ | 1 | 1 | -- | -- |
Rear Demist Relay Control | B0283 02 | B0283 05 | B0283 05 | -- |
Rear Demist Relay Coil Ground | -- | B0283 05 | -- | -- |
1. Rear Demister Inoperative |
When the HVAC control module receives a rear window demist request from the HVAC control faceplate, the HVAC control module will supply voltage to the relay coil. Battery positive voltage is supplied at all times to the relay switched input and the relay coil is always grounded. This allows battery positive voltage from the relay switched input to flow through the switch contacts and out the relay switched output to the rear window demister grid.
Battery voltage must be between 9-16 V.
The HVAC control module detects a short to ground in the relay control circuit.
The HVAC control module detects a short to voltage or an open/high resistance in the relay control circuit.
• | If B0283 02 is current, the rear window demister grid will operate continuously. |
• | If B0283 05 is current, the rear window demister grid will be inoperative. |
• | The DTC will be current for as long as the fault is present. |
• | When the fault is no longer present, the DTC will be a history DTC. |
• | A history DTC will clear after 50 ignition cycles. |
Rear Window Defogger Description and Operation
Control Module References for scan tool information
Engine running, command the E18 rear window defogger grid ON and OFF with a scan tool. The E18 rear window defogger grid should turn ON and OFF when changing between the commanded states.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the K33 HVAC control module. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K33 HVAC control module. |
⇒ | If not within the specified range, replace the K17 rear demist relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified value, replace the K17 rear demist relay. |
⇒ | If greater than the specified range, replace the K17 rear demist relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for HVAC control module replacement, setup and programming |
© Copyright Chevrolet. All rights reserved |