Water Outlet Installation

  1. Clean the sealing surfaces.

  2. 2371590
  3. Install the water outlet (2) and 2 NEW water outlet seal rings (3).
  4. Caution: Refer to Fastener Caution in the Preface section.

  5. Install the 4 water outlet bolts (1) and tighten to 8 N·m (71 lb in).
   