To the top of the document
Volt
   
GMDE Start Page Load static TOC Load dynamic TOC Help?

Drive Motor Power Inverter Module Cooling Inlet Hose Replacement


2392405

Callout

Component Name

Preliminary Procedure

  1. Drain the coolant. Refer to Drive Motor Generator Power Inverter Module Cooling System Draining and Filling
  2. Remove the drive motor generator power inverter module cover. Refer to Drive Motor Generator Power Inverter Module Cover Replacement
  3. Remove the front compartment front sight shield. Refer to Front Compartment Front Sight Shield Replacement : Volt → Ampera

1

Drive Motor Power Inverter Module Cooling Inlet Hose Quick Connect.

Procedure

Release clip and slide hose off fitting.

2

Drive Motor Power Inverter Module Cooling Inlet Hose Quick Connect.

Procedure

Release clip and slide hose off fitting.

3

Drive Motor Power Inverter Module Cooling Inlet Hose Retainer.

4

Drive Motor Power Inverter Module Cooling Inlet Hose.

Tip
Replace corroded hose clamps and brackets.

   


© Copyright Chevrolet. All rights reserved