Using Fused Jumper Wires

Special Tools

EL 35616-20F Fused Jumper Wire

For equivalent regional tools, refer to Special Tools .

Danger: This procedure should not be performed on high voltage circuits. Performing this procedure on high voltage circuits may result in serious injury or death.

Note: A fused jumper may not protect solid state components from being damaged.


2389094

The EL 35616-20F Fused Jumper Wire includes banana jack connectors that provide adaptation to most connectors without damage. This fused jumper wire is supplied with a 20 A fuse which may not be suitable for some circuits. Do not use a fuse with a higher rating than the fuse that protects the circuit being tested.

   