Volt |
||||||||
|
|
• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Garage Door Opener Switch Amber LED Control | B2625 02 | 1 | 1 | -- |
Garage Door Opener Switch Ground | -- | 1 | -- | -- |
1. Interior Backlighting Malfunction |
The instrument panel dimmer switch is used to increase and decrease the brightness of the interior backlighting components. The instrument panel dimmer switch provides a voltage signal to the body control module (BCM) that will increase as the brightness of the lights are increased and decrease as the brightness of the lights are decreased. The BCM provides a low reference, signal, and B+ voltage reference circuits to the instrument panel dimmer switch. When the instrument panel dimmer switch is placed in the desired position, the dimmed voltage setting is applied from the instrument panel dimmer switch through the instrument panel dimmer switch signal circuit to the BCM. The BCM interprets the signal and applies a pulse width modulated (PWM) voltage through the garage door opener switch amber LED indicator control circuit illuminating the garage door opener switch amber LED to the requested level of brightness.
• | Battery voltage must be between 9-16 V. |
• | Sidelights ON. |
The BCM detects a short to ground in the garage door opener switch amber LED control circuit.
The garage door opener switch amber LED is inoperative.
• | The condition responsible for setting the DTC no longer exists. |
• | A history DTC will clear once 100 consecutive malfunction free vehicle ON/OFF switch cycles have occurred. |
Interior Lights Dimming Schematics
Interior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the K9 Body Control Module. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K9 Body Control Module. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, programming and setup |
©© Copyright Chevrolet. All rights reserved |