To the top of the document
Volt
   
GMDE Start Page Load static TOC Load dynamic TOC Help?

Centre Pillar Inner Panel Replacement

Removal Procedure

Warning : Refer to Approved Equipment for Collision Repair Warning in the Preface section.

Warning : Refer to Glass and Sheet Metal Handling Warning in the Preface section.

  1. Disable the SIR system. Refer to SIR Disabling and Enabling .
  2. Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.

    The High Voltage Disabling procedure will perform the following tasks:

       • Identify how to disable high voltage.
       • Identify how to test for the presence of high voltage.
       • Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.
    Failure to follow the procedures exactly as written may result in serious injury or death.

  3. Disable the high voltage system. Refer to High Voltage Disabling .
  4. Remove all related panels and components.
  5. Visually inspect the damage. Repair as much of the damage as possible.
  6. Remove the sealers and anti-corrosion materials from the repair area as necessary.

  7. 2643512
  8. Locate and mark all the necessary factory welds of the centre pillar inner panel (1).
  9. Drill all factory welds. Note the number and location of welds for installation of the service assembly.

  10. 2643513
  11. Remove the damaged centre pillar inner panel (1).

Installation Procedure


    2643514
  1. Create 3 5x18 mm slots (2) for MIG-brazing to the centre pillar inner panel (1).
  2. Prepare all mating surfaces as necessary.
  3. Clean and prepare the attaching surfaces for spot welding and brazing.

  4. 2643513
  5. Position the centre pillar inner panel (1) on the vehicle.
  6. Verify the fit of the center pillar inner panel.
  7. Clamp the center pillar inner panel into position.

  8. 2643515
  9. Install the centre pillar inner panel (1) accordingly.
  10. 7.1. Upper flange (2) - 3 5x18 mm slot brazes
    7.2. Upper flange (3) - 2 spot welds
    7.3. Lower flange (4) - 4 spot welds
  11. Apply the sealers and anti-corrosion materials to the repair area as necessary.
  12. Paint the repaired area.
  13. Install all related panels and components.
  14. Enable the high voltage system. Refer to High Voltage Enabling .
  15. Enable the SIR system. Refer to SIR Disabling and Enabling .
   


&#169© Copyright Chevrolet. All rights reserved