Cruze
Exhaust Gas Recirculation Valve Adapter Replacement
Removal Procedure
Open the bonnet.
Remove the exhaust gas recirculation pipe. Refer to
Exhaust Gas Recirculation Pipe Replacement
.
Remove the exhaust gas recirculation valve. Refer to
Exhaust Gas Recirculation Valve Replacement
.
Remove the 2 exhaust gas recirculation valve adapter bolts (1).
Remove the exhaust gas recirculation valve adapter (2).
Remove the exhaust gas recirculation valve adapter gasket (3).
Installation Procedure
Install the new exhaust gas recirculation valve adapter gasket (3).
Install the exhaust gas recirculation valve adapter (2).
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the 2 exhaust gas recirculation valve adapter bolts (1) and tighten to
25 N·m (18 lb ft).
Install the exhaust gas recirculation valve. Refer to
Exhaust Gas Recirculation Valve Replacement
.
Install the exhaust gas recirculation pipe. Refer to
Exhaust Gas Recirculation Pipe Replacement
.
Close the bonnet.
© Copyright Chevrolet. All rights reserved